Atomic Absorption Spectrophotometer TRAS-701

Atomic Absorption Spectrophotometer TRAS-701

Atomic Absorption Spectrophotometer TRAS-701is completely controlled by a computer. It has a fully automatic control system with advanced temperature control technology of a graphite furnace. With a wavelength range of 190 to 900 nm. Providing a spectral bandwidth of 0.1, 0.2, 0.4, 1.0, and 2.0 nm. The setting of the background deduction method. The fast heating capacity can improve the elements' flexibility even more. . It presents the hollow cathode lamp in its operational state. It is a safe, dependable, and convenient flame system with a multi-functional software workstation.

Catalog
Wavelength range  190 to 900 nm
Spectral bandwidth 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Accuracy of the wavelength ±0.15 nm
Receptivity of the wavelength  ≤0.04 nm
Baseline stability ≤0.002A/30 min (Cu)
Characteristic viscosity 0.02 μg/ml/1% (Cu)
Checking limit 0.004 μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/ mm
Inflamer All-metal titanium burner
Atomizer  Effective glass atomizer
Lamp stand 8
D2 background correction ability When the background is 1 A, the background ability should be deducted not less than 50 times, self-absorption background deduction method
Size  700 mm×550 mm×450 mm  
weight 75 Kg
Power source 220V±22V AC
Flame System 100 mm, ≤0.006 A/30 min, ≤0.025 μg/ml/1%, ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008 μg/ml), Can Automatically cut off the gas when The pressure is not enough, The power is off, flameout and unconformity of the burner.
Graphite furnace 3000 ℃, ≥2000 ℃/S, Cd≤0.5×10 to12 g<hr> Cu≤0.5×10 to 11 g, Cu≤3% Cd≤3 %, 550 mm×450 mm×300 mm  65 Kg
Power source and power 220 V±22 V  AC  7000 W
  • The hollow cathode lamp's operational state
  • Wavelength searching and peak search are completely automatic
  • The integrated floated optical platform design improves the optical system's shock resistance and stability when using the optical signal for an extended period
  • Eight light stands can be changed automatically while simultaneously preheating and optimizing the eight lights
  • Adjustable position: It can automatically set the front and rear positions, as well as the best height for the flame burner
  • The setting of the background deduction method
  • Background self-absorption and the Deuterium lamp
  • Data processing, super-strong database with over 500 data self-storage and cut-off storage functions
  • can hold the analysis results in form of a Spreadsheet, and the test procedure and result can be called at random
  • The flame results demonstrated and the emissions technique are two methods for measuring
  • Result printing: parameter printing, data result printing, and diagram printing
  • It has fully automatic controlled, with the help of the software
  • The selection of lamp elements, Front-to-rear lifter adjustment (up/down)
  • Re-adjustment of optical energy, selecting the slit, Determination of wavelength scanning and peak searching, sixth, choosing an atomizer
  • Full safety chain protection, warning and automatic protection against incorrect burner, gas leakage, air under voltage, and abnormal flameout
  • Managing the flow of gas
  • Auto-flaming and extinguishing
  • Temperature control technology of graphite furnace advanced
  • Introducing PID technology can effectively overcome the influence on the temperature rising procedure
  • The combination of the 3ms/time fast sampling technique can result in more accurate and dependable testing data
  • The fast heating capacity can improve the elements' flexibility even more
  • Use a standard 220V power source instead of a 380V dynamic power source
  • The maximum procedure heating capacity setting of 20 levels can make testing multiple samples more efficient and comfortable
  • Three grades of adjustable gas flow can be tailored to meet a variety of application requirements
  • Can provide a timely warning when the gas and water are turned off and there is insufficient gas and water, thereby avoiding equipment damage and measurement error
  • Safe, reliable, and convenient flame system
  • EPC can more precisely control the flow of acetylene (C2H2) and is a type of system that is also simple to operate
  • A well-functioning Tomi Ziti on the system allows for greater sensitivity
  • The entire operating system is highly secure because the fire safety system scan alert for the fluctuation
  • It will also automatically turn off the gas and prohibit temper tantrums
  • Protects the operating personnel and equipment from harm and damage
  • Multi-functional software workstation, a working computer that is supported WINDOWS XP/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000
  • The extensive menu makes it easy for customers to use
  • Easy conversion between different menus simplifies the operation
  • A variety of analytical correction methods gives users more options
  • The basic default parameter settings allow even inexperienced users to perform routine operations
  • Flexible storage, editing, and printing methods provide the most support to the user

Atomic Absorption Spectrophotometers

Atomic Absorption Spectrophotometer TRAS-601

  • Wavelength Range : 190 to 900 nm
  • Wavelength Accuracy : £ ±0.5 nm
Catalog

Micro Spectrophotometer

Micro Spectrophotometer TRMS-604
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1 nm
Catalog
Micro Spectrophotometer TRMS-605
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1nm
Catalog

Micro-Spectrophotometer TRMS-601

  • Light Path : 1mm
  • sample Volume : 1 to 2μL
Catalog

Micro-spectrophotometer TRMS-602

  • Optical Path : 1/0.5/0.05 mm automatic conversion
  • Optical Range : 190 to 1100 nm
Catalog

Micro-spectrophotometer TRMS-603

  • Wavelength scanning Range : 190 to 850 nm
  • Wavelength Accuracy : ±1 nm
Catalog
X-ray Fluorescence Spectrometer

Energy Dispersion X-ray Fluorescence Spectrometer TRXS-601
  • Analysis Principle : Energy-dispersive X-ray fluorescence analysis
  • Element Measuring Range : Any element from Na(11)-U(92)
Catalog

Fluorescence Spectrophotometer TRFS-601

  • Exciting Optical Filters : Interface optical filter (10 nm bandwidth)
  • Wavelength : 365 nm
Catalog

Double Beam UV VIS Spectrophotometer

Double Beam UV VIS Spectrophotometer TRDUV-604

  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
Catalog
Double Beam UV VIS Spectrophotometer TRDUV-601
  • Spectrum Bandwidth : 2 nm
  • Wavelength Range : 190 to 1100 nm
Catalog
Double Beam UV VIS Spectrophotometer TRDUV-602
  • Spectrum Bandwidth : 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
  • Wavelength Range : 190 to 1100 nm
Catalog

Double Beam UV VIS Spectrophotometer TRDUV-603

  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
Catalog

Single Beam UV VIS Spectrophotometer

Single Beam UV VIS Spectrophotometer TRSUV-605

  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
Catalog
Single Beam UV VIS Spectrophotometer TRSUV-606
  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
Catalog
Single Beam UV VIS SpectrophotometerTRSUV-601
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
Catalog

Single Beam UV VIS SpectrophotometerTRSUV-602

  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
Catalog

Single Beam UV VIS SpectrophotometerTRSUV-607

  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
Catalog

Single Beam UV VIS SpectrophotometerTRSUV-608

  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
Catalog
Single Beam UV VIS SpectrophotometerTRSUV-603
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
Catalog
Single Beam UV VIS SpectrophotometerTRSUV-604
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
Catalog

Visible Spectrophotometer

Visible Spectrophotometer TRVS-601

  • Photometry : Single beam
  • Monochromatic Type : Littrow
Catalog

NIR Spectrophotometer

Spectrophotometer TRNS-601
  • Wavelength Range : 900 to 1700 nm
  • Wavelength  Accuracy : ±1 nm
Catalog