Atomic Absorption Spectrophotometer TRAS-601

Atomic Absorption Spectrophotometer TRAS-601

Atomic Absorption Spectrophotometer TRAS-601is an integrated computer data processing device whose wavelength ranges from 190 to 900nm. Spectrum bandwidth with ranges of 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm. Special devices for quick gas conversion and safety protection can be used to analyze air-acetylene and nitrogen oxide flames, extending the analytic elements to over 60. In addition, it has an LCD. It is a long-life and corrosion-resistant atomization system. The device is stable and dependable. To achieve a stable flame and low noise, the gas path system is outfitted with highly precise pressure and existing stabilizing devices.

Catalog
Wavelength Range 190 to 900 nm
Wavelength Accuracy £ ±0.5 nm
Wavelength Repeatability £ 0.3 nm (single direction)
Spectrum Bandwidth 0.2 nm, 0.4 nm, 0.7nm, 1.4 nm, 2.4 nm, 5.0 nm
Resolution <40%
Baseline stability ±0.004 Abs/30 min
Characteristic concentration of copper £ 0.04 mg/ml/1%
Detection limit of copper £0.008 mg/ml
Background calibration ability Greater than 30 times
RS232 including
Printer optional
Power supply 220V 3A, 50 Hz
Package Dimensions 1220×770×730 mm (Main instrument) 800×400×900 mm ( Accessories )
Weight 160 Kg
  • Built-in computer data processing and LCD
  • It is stable and dependable
  • With functions such as integral holding, peak height and area, auto-zero adjusting, deuterium lamp background correction
  • Multi-linear and nonlinear curve fitting, various parameters and working curves displayed on the screen, report printing, and so on
  • It has an interface for externally connecting PCs
  • Stability, to achieve better basic line stability, a double system will automatically recompense for the source of light drift and waveform drift induced by temperature variations
  • Quickly, the cathode lamp does not need to be preheated for an extended period, and the sample can be analyzed immediately
  • It is the preferred instrument by users for conducting various types’ elements methods and fast sample analysis
  • Used to eliminate color differences across the entire spectrum
  • A round light spot from the light source is chemically converted into a long white spot that enters the slit. As a result, the light flux of the double beam is increased
  • Long-life and corrosion-resistant atomization system
  • The burner is made of a new type of titanium alloy that is anti-corrosive and has a quick thermalequilibrium
  • Multi-functional analysis mode. For flame absorption, emission, particle permeability in graphite furnaces, and hydride generation methods
  • A gas path system that is both safe and reliable
  • Special devices for quick gas conversion and safety protection
  • It analyses air-acetylene and nitrogen oxides flames, extending the analytic elements to over 60
  • When the device is purchased, it will come with a complete set of accessories and will be ready to use

Atomic Absorption Spectrophotometers

Atomic Absorption Spectrophotometer TRAS-701

  • Wavelength range  : 190 to 900 nm
  • Spectral bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Catalog

Micro Spectrophotometer

Micro Spectrophotometer TRMS-604
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1 nm
Catalog
Micro Spectrophotometer TRMS-605
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1nm
Catalog

Micro-Spectrophotometer TRMS-601

  • Light Path : 1mm
  • sample Volume : 1 to 2μL
Catalog

Micro-spectrophotometer TRMS-602

  • Optical Path : 1/0.5/0.05 mm automatic conversion
  • Optical Range : 190 to 1100 nm
Catalog

Micro-spectrophotometer TRMS-603

  • Wavelength scanning Range : 190 to 850 nm
  • Wavelength Accuracy : ±1 nm
Catalog
X-ray Fluorescence Spectrometer

Energy Dispersion X-ray Fluorescence Spectrometer TRXS-601
  • Analysis Principle : Energy-dispersive X-ray fluorescence analysis
  • Element Measuring Range : Any element from Na(11)-U(92)
Catalog

Fluorescence Spectrophotometer TRFS-601

  • Exciting Optical Filters : Interface optical filter (10 nm bandwidth)
  • Wavelength : 365 nm
Catalog

Double Beam UV VIS Spectrophotometer

Double Beam UV VIS Spectrophotometer TRDUV-604

  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
Catalog
Double Beam UV VIS Spectrophotometer TRDUV-601
  • Spectrum Bandwidth : 2 nm
  • Wavelength Range : 190 to 1100 nm
Catalog
Double Beam UV VIS Spectrophotometer TRDUV-602
  • Spectrum Bandwidth : 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
  • Wavelength Range : 190 to 1100 nm
Catalog

Double Beam UV VIS Spectrophotometer TRDUV-603

  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
Catalog

Single Beam UV VIS Spectrophotometer

Single Beam UV VIS Spectrophotometer TRSUV-605

  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
Catalog
Single Beam UV VIS Spectrophotometer TRSUV-606
  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
Catalog
Single Beam UV VIS SpectrophotometerTRSUV-601
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
Catalog

Single Beam UV VIS SpectrophotometerTRSUV-602

  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
Catalog

Single Beam UV VIS SpectrophotometerTRSUV-607

  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
Catalog

Single Beam UV VIS SpectrophotometerTRSUV-608

  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
Catalog
Single Beam UV VIS SpectrophotometerTRSUV-603
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
Catalog
Single Beam UV VIS SpectrophotometerTRSUV-604
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
Catalog

Visible Spectrophotometer

Visible Spectrophotometer TRVS-601

  • Photometry : Single beam
  • Monochromatic Type : Littrow
Catalog

NIR Spectrophotometer

Spectrophotometer TRNS-601
  • Wavelength Range : 900 to 1700 nm
  • Wavelength  Accuracy : ±1 nm
Catalog